| Apr-2006 |
N
|
UFGS 22 15 26.00 20 High and Medium Pressure Compressed Air Piping |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15212N (August 2004) |
| Apr-2006 |
A
|
UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems |
Apr-2006 |
R
|
|
Removed information on extractors and fibrous glass ductwork |
| Apr-2006 |
N
|
UFGS 23 08 01.00 20 Testing Industrial Ventilation Systems |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15951N (September 1999) |
| Apr-2006 |
N
|
UFGS 23 21 13.00 20 Low Temperature Water (LTW) Heating System |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15185N (September 1999) |
| Apr-2006 |
N
|
UFGS 23 51 43.01 20 Mechanical Cyclone Dust Collector of Flue Gas Particulates |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15861N (September 1999) |
| Apr-2006 |
N
|
UFGS 23 51 43.02 20 Electrostatic Dust Collector of Flue Gas Particulates |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15862N (September 1999) |
| Apr-2006 |
N
|
UFGS 23 52 53.00 20 Steam Boilers and Equipment (18,000,000 - 60,000,000 Btu/hr) |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15517N (June 2005) |
| Apr-2006 |
N
|
UFGS 23 83 00.00 20 Electric Space Heating Equipment |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15768N (September 1999) |
| Apr-2006 |
A
|
UFGS 25 08 10 Utility Monitoring and Control System Testing |
Apr-2006 |
N
|
|
New section |
| Apr-2006 |
N
|
UFGS 26 05 33 Dockside Power Connection Stations |
Apr-2006 |
R
|
|
Thorough revision of section; retitled (formerly 480 V PIER POWER OUTLET ASSEMBLIES) |
| Apr-2006 |
N
|
UFGS 26 27 29 Marina Electrical Work |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16407 (August 2004) |
| Apr-2006 |
N
|
UFGS 26 29 23 Adjustable Speed Drive (ASD) Systems Under 600 Volts |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16261 (August 2004) |
| Apr-2006 |
N
|
UFGS 26 36 23.00 20 Automatic Transfer Switches |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16410N (February 2003) |
| Apr-2006 |
N
|
UFGS 26 42 13.00 20 Cathodic Protection by Galvanic Anodes |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-13110N (September 2000) |
| Apr-2006 |
N
|
UFGS 26 42 19.00 20 Cathodic Protection by Impressed Current |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-13111N (August 2001) |
| Apr-2006 |
N
|
UFGS 26 55 80 Surgical, Procedure and Exam Lighting Fixtures |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16553N (September 1999) |
| Apr-2006 |
A
|
UFGS 27 05 14.00 10 Cable Television Premises Distribution System |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16815A (December 2004) |
| Apr-2006 |
N
|
UFGS 27 21 00.00 20 Intercommunication System |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16822N (August 2003) |
| Apr-2006 |
A
|
UFGS 27 41 16.00 10 Television Signal Reception System |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16785A (December 2004) |
| Apr-2006 |
A
|
UFGS 27 51 16 Public Address Systems |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16770 (November 2003) |
| Apr-2006 |
N
|
UFGS 27 54 00.00 20 Community Antenna Television (CATV) |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16783N (February 2003) |
| Apr-2006 |
N
|
UFGS 28 16 00.00 20 Basic Intrusion Detection System (IDS) |
Apr-2006 |
R
|
|
Requires conformance to DM 13.02 |
| Apr-2006 |
N
|
UFGS 28 20 00.00 20 Electronic Security Systems (ESS) Commercial |
Apr-2006 |
R
|
|
Requires conformance to DM 13.02; retitled (formerly COMMERCIAL INTRUSION DETECTION SYSTEMS (IDS)) |
| Apr-2006 |
N
|
UFGS 28 31 33.13 20 Exterior Fire Reporting System, Radio Type |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-13853N (August 2003) |
| Apr-2006 |
N
|
UFGS 28 31 49 Carbon Monoxide Detectors |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-13856 (August 2004) |
| Apr-2006 |
N
|
UFGS 31 62 13.13 Cast-In-Place Concrete Piles |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02459 (August 2004) |
| Apr-2006 |
N
|
UFGS 31 62 13.26 Pressure-Injected Footings |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02466 (August 2004) |
| Apr-2006 |
N
|
UFGS 32 01 19.61 Sealing of Joints in Rigid Pavement |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02982 (August 2004) |
| Apr-2006 |
N
|
UFGS 32 11 36.13 Lean Concrete Base Course |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02712 (August 2004) |
| Apr-2006 |
N
|
UFGS 32 92 23 Sodding |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02922 (May 2004) |
| Apr-2006 |
N
|
UFGS 33 16 13.16 Wire-Wound Circular Prestressed-Concrete Water Tank |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-13208 (August 2004) |
| Apr-2006 |
N
|
UFGS 33 63 13 Exterior Underground Steam Distribution System |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02553 (August 2004) |
| Apr-2006 |
N
|
UFGS 33 63 14 Exterior Buried Pumped Condensate Return |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02556 (August 2004) |
| Apr-2006 |
N
|
UFGS 33 63 23 Exterior Aboveground Steam Distribution |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02554 (August 2004) |
| Apr-2006 |
N
|
UFGS 33 82 00 Telecommunications Outside Plant (OSP) |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-16711 (August 2004) |
| Apr-2006 |
N
|
UFGS 35 20 23 Dredging |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02325 (August 2004) |
| Apr-2006 |
N
|
UFGS 35 51 13.00 20 Concrete Floating Pier for Small Craft |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-03420N (August 2004) |
| Apr-2006 |
N
|
UFGS 35 59 13.19 Arch-Type Rubber Marine Fenders |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-02397 (May 2003) |
| Apr-2006 |
N
|
UFGS 40 17 26.00 20 Welding Pressure Piping |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15216N (September 1999) |
| Apr-2006 |
N
|
UFGS 43 15 00.00 20 Low Pressure Compressed Air Piping (Non-Breathing Air Type) |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-15211N (August 2003) |
| Apr-2006 |
N
|
UFGS 43 21 29 Flow Measuring Equipment (Potable Water) (Sewage Treatment Plant) |
Apr-2006 |
R
|
|
To conform with CSI MasterFormat, replacing without change UFGS-13401 (August 2004) |