| May-2026 |
N
|
UFGS 01 11 00 Summary of Work |
Feb-2024 |
C
|
2 |
In response to CCR 17030, updated paragraph "Location of Underground Utilities" (1.5) to verify utility locations within the area of work. |
| May-2026 |
N
|
UFGS 01 78 23 Operation and Maintenance Data |
May-2023 |
C
|
3 |
In response to CCR 17227, changed "Record Drawings and Utility Systems" to "Utility Systems" in Submittals and as paragraph title for 1.6.6.7; also updated paragraph 1.6.6.7. |
| May-2026 |
N
|
UFGS 08 39 55.00 20 Navy Standard Earth-Covered Magazine Doors |
Nov-2024 |
C
|
1 |
Removed shop coating requirement for Navy ECM blast doors from paragraph Finishes (2.6). |
| May-2026 |
N
|
UFGS 08 56 46.10 20 Radio Frequency Shielded Enclosures, Demountable Type |
Aug-2011 |
D
|
|
Superseded by UFGS-13 49 33.70 TEMPEST [DEMOUNTABLE] [TRANSPORTABLE] [MODULAR] RADIO FREQUENCY INTERFERENCE (RFI) SHIELDED ENCLOSURE.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 09 97 13.15 20 Low VOC Flexible Interior Coating of Steel Fuel Tanks |
May-2026 |
N
|
|
This section has been renumbered and posted as new - for NAVY USE ONLY |
| May-2026 |
N
|
UFGS 13 49 20 Radio Frequency (RF) Shielding |
May-2026 |
N
|
|
New unified section for radio frequency (RF) shielding of fixed facilities; Superseding UFGS-13 49 20.00 10 RFI/EMI SHIELDING. |
| May-2026 |
A
|
UFGS 13 49 20.00 10 RFI/EMI Shielding |
Oct-2007 |
D
|
|
Superseded by UFGS-13 49 20 RADIO FREQUENCY (RF) SHIELDING and UFGS-13 49 30 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) SHIELDING.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 13 49 30 High-Altitude Electromagnetic Pulse (HEMP) Shielding |
May-2026 |
N
|
|
New unified section superseding UFGS-13 49 20.00 10 RFI/EMI SHIELDING. |
| May-2026 |
N
|
UFGS 13 49 33.70 Tempest [Demountable] [Transportable] [Modular] Radio Frequency Interference (RFI) Shielded Enclosure |
May-2026 |
N
|
|
New unified section superseding UFGS-08 56 46.10 20 RADIO FREQUENCY SHIELDED ENCLOSURES, DEMOUNTABLE TYPE. |
| May-2026 |
N
|
UFGS 23 51 43.00 20 Dust and Gas Collector, Dry Scrubber and Fabric Filter Type |
Feb-2010 |
D
|
|
Archived with no replacement; specification obsolete/low usage.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 23 51 43.01 20 Mechanical Cyclone Dust Collector of Flue Gas Particulates |
Apr-2006 |
D
|
|
Archived with no replacement; specification obsolete/low usage.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 23 51 43.02 20 Electrostatic Dust Collector of Flue Gas Particulates |
Apr-2006 |
D
|
|
Archived with no replacement; specification obsolete/low usage.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 23 51 43.03 20 Fabric Filter Dust Collector of Fly Ash Particles in Flue Gas |
Feb-2010 |
D
|
|
Archived with no replacement; specification obsolete/low usage.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 23 52 33.01 20 Steam Heating Plant Watertube (Shop Assembled) Coal/Oil or Coal |
Nov-2008 |
C
|
4 |
In response to archived UFGS sections referenced in this section, the note and text for paragraph AIR POLLUTION CONTROL EQUIPMENT (2.13) were updated. |
| May-2026 |
N
|
UFGS 23 52 33.02 20 Steam Heating Plant Watertube (Field Erected) Coal/Oil or Coal |
Nov-2008 |
C
|
6 |
In response to archived UFGS sections referenced in this section, the note and text for paragraphs AIR POLLUTION CONTROL EQUIPMENT (2.13) and Scrubbers (2.13.1) were updated. |
| May-2026 |
N
|
UFGS 23 69 00.00 20 Refrigeration Equipment for Cold Storage |
Jul-2006 |
D
|
|
Superseded by UFGS-23 63 00.00 Cold Storage Refrigeration Systems.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 26 41 00 Lightning Protection System |
May-2026 |
R
|
|
Complete review and update. |
| May-2026 |
A
|
UFGS 31 33 40 Foundation Drilling and Grouting in Rock through Concrete Structures |
May-2026 |
N
|
|
New Section superseding UFGS-31 43 13.13 CONCRETE PRESSURE GROUTING. |
| May-2026 |
A
|
UFGS 31 43 13.13 Concrete Pressure Grouting |
Feb-2021 |
D
|
|
Superseded by UFGS 31 33 40 FOUNDATION DRILLING AND GROUTING IN ROCK THROUGH CONCRETE STRUCTURES.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 33 71 02 Underground Electrical Distribution |
Feb-2026 |
C
|
1 |
Updated content of "Construction" paragraph (2.14.2.3); updated "Joints" paragraph (2.14.2.4) to include shiplap. |
| May-2026 |
A
|
UFGS 34 11 00 Rail Tracks |
May-2026 |
R
|
|
Complete review and update, to include title change from RAILROAD TRACK AND ACCESSORIES to RAIL TRACKS |
| May-2026 |
N
|
UFGS 41 22 13.16 Gantry Cranes |
Apr-2008 |
D
|
|
Archived; For more information, contact Navy Crane CenterSee also NAVCRANECENINST 11450.1D of 14 August 2025Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| May-2026 |
N
|
UFGS 41 22 13.19 Jib Cranes |
May-2025 |
C
|
1 |
Large update with numerous terminology adjustments, document reorganization, and formatting tweaks to ensure alignment with associated equipment specifications. |
| May-2026 |
N
|
UFGS 41 22 13.55 Bridge Cranes, Aircraft Maintenance Hangar |
Nov-2025 |
C
|
1 |
Minor terminology adjustments and formatting tweaks to ensure alignment with associated equipment specifications. |
| May-2026 |
N
|
UFGS 41 22 23.19 Monorail Hoists |
May-2025 |
C
|
1 |
Large update with numerous terminology adjustments, document reorganization, and formatting tweaks to ensure alignment with associated equipment specifications. |
| May-2026 |
N
|
UFGS 46 25 14 Coalescing [or Vertical Tube] Oil-Water Separators |
Feb-2011 |
D
|
|
Section has been Archived with no replacement.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Feb-2026 |
A
|
UFGS 03 70 00 Mass Concrete |
Feb-2026 |
R
|
|
Complete review and update. |
| Feb-2026 |
N
|
UFGS 07 56 00.60 Mesh Reinforced Elastomeric Coating (MREC) Roofing |
Aug-2025 |
C
|
1 |
In response to CCR 17084, updated Base and Intermediate Coat and Fabric Components (3.4.2) to clarify that manufacturer's instructions should be followed for the specific roof type to which the membrane is being applied. |
| Feb-2026 |
A
|
UFGS 08 33 23 Overhead Coiling Doors |
Aug-2020 |
C
|
2 |
Incorporated various CCRs. |
| Feb-2026 |
N
|
UFGS 13 31 33 Frame Supported Membrane Structures for Protection of Aircraft |
Feb-2023 |
D
|
|
Superseded by UFGS-13 31 34 FRAME SUPPORTED MEMBRANE STRUCTURES FOR AIRCRAFT HANGARS OR PROTECTION OF AIRCRAFT.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Feb-2026 |
N
|
UFGS 13 31 34 Frame Supported Membrane Structures for Aircraft Hangars or Protection of Aircraft |
Feb-2026 |
N
|
|
New UFGS to address frame supported membrane structures for use on airfields for either an aircraft hangar or for protection of aircraft (weather, sunshade, environmental shelter). This section supersedes UFGS-13 31 33 FRAME SUPPORTED MEMBRANE STRUCTURES FOR PROTECTION OF AIRCRAFT. |
| Feb-2026 |
N
|
UFGS 13 50 00 Ignitable Liquid Drainage Floor Assemblies |
Feb-2026 |
N
|
|
New UFGS Section to address ignitable liquid drainage floor assemblies, including their peripheral equipment and controls. |
| Feb-2026 |
A
|
UFGS 26 05 19.00 10 Insulated Wire and Cable |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 26 05 33 Dockside Power Connection Stations |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 26 11 13.00 20 Primary Unit Substation |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 26 11 14.00 10 Main Electric Supply Station and Substation |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 26 13 13 Metal-Clad Switchgear |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 26 20 00 Interior Distribution System |
May-2025 |
C
|
2 |
In response to several CCRs, updates have been made to paragraphs Conductors (2.7.1) and Motors (2.17); also CCR 17516, MET/ENG tags have been added to conductor sizes throughout the section. |
| Feb-2026 |
A
|
UFGS 26 28 00.00 10 Motor Control Centers, Switchboards and Panelboards |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 26 29 23 Adjustable Speed Drive (ASD) Systems Under 600 Volts |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 26 31 00 Facility-Scale Solar Photovoltaic (PV) Systems |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 26 32 15 Engine-Generator Set Stationary 15-2500 kW, with Auxiliaries |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 26 36 23 Automatic Transfer Switches and By-Pass/Isolation Switch |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 26 42 13 Galvanic (Sacrificial) Anode Cathodic Protection (GACP) System |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 26 42 15 Cathodic Protection System for the Interior of Steel Water Tanks |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 26 42 17 Impressed Current Cathodic Protection (ICCP) System |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 27 41 00 Audio-Visual Systems |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 33 26 00.00 10 Relief Wells |
Feb-2026 |
R
|
|
Complete review and update. |
| Feb-2026 |
N
|
UFGS 33 71 01 Overhead Transmission and Distribution |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 33 71 02 Underground Electrical Distribution |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 33 82 00 Telecommunications Outside Plant (OSP) |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
A
|
UFGS 35 20 20 Electrical Equipment for Gate Hoist |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS 48 15 00 Wind Generator System |
Feb-2026 |
R
|
|
Updated to incorporate various CCRs. |
| Feb-2026 |
N
|
UFGS Section Template (Template CCRs Only) |
Feb-2026 |
R
|
|
Complete review and update. |
| Nov-2025 |
N
|
UFGS 01 78 23 Operation and Maintenance Data |
May-2023 |
C
|
2 |
In response to CCR 17101, metric units have been corrected in General Facility and Systems Description paragraph (1.6.2.1) |
| Nov-2025 |
N
|
UFGS 22 15 19.13 20 Large Nonlubricated Reciprocating Air Compressors (Over 300 HP) |
Nov-2009 |
D
|
|
Superseded by new unified section UFGS-22 15 19.13 LARGE NONLUBRICATED RECIPROCATING AIR COMPRESSORS (OVER 100 HP)Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Nov-2025 |
A
|
UFGS 22 15 19.13 Large Nonlubricated Reciprocating Air Compressors (Over 100 HP) |
Nov-2025 |
N
|
|
Superseding UFGS 22 15 19.13 20 LARGE NONLUBRICATED RECIPROCATING AIR COMPRESSORS (OVER 300 HP). Complete review and update including section number and title changes. |
| Nov-2025 |
N
|
UFGS 22 15 19.19 20 Nonlubricated Rotary Screw Air Compressors (100 HP and Larger) |
May-2011 |
D
|
|
Superseded by new unified section UFGS-22 15 19.19 NONLUBRICATED ROTARY SCREW AIR COMPRESSORS (100 HP AND LARGERNote: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Nov-2025 |
A
|
UFGS 22 15 19.19 Nonlubricated Rotary Screw Air Compressors (100 HP and Larger) |
Nov-2025 |
N
|
|
Superseding UFGS 22 15 19.19 20 NONLUBRICATED ROTARY SCREW AIR COMPRESSORS (100 HP AND LARGER). Complete review and update including section number change. |
| Nov-2025 |
A
|
UFGS 22 15 26 Compressed Air Piping Systems (Up to 5000 PSI) |
Nov-2025 |
N
|
|
Superseding UFGS 22 15 26.00 20 HIGH AND MEDIUM PRESURE COMPRESSED AIR PIPING SYSTEMS (UP TO 5000 PSI). Complete review and update including section number and title changes. |
| Nov-2025 |
N
|
UFGS 22 15 26.00 20 High and Medium Pressure Compressed Air Piping |
Apr-2006 |
D
|
|
Superseded by new unified section UFGS-22 15 26 COMPRESSED AIR PIPING SYSTEMS (UP TO 5000 PSI)Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Nov-2025 |
N
|
UFGS 22 16 19.26 20 Large Centrifugal Air Compressors (Over 200 HP) |
Nov-2009 |
D
|
|
Superseded by new unified section UFGS-22 16 19.26 Large Centrifugal Air Compressors (Over 100 HP)Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Nov-2025 |
A
|
UFGS 22 16 19.26 Large Centrifugal Air Compressors (Over 100 HP) |
Nov-2025 |
N
|
|
Superseding UFGS 22 16 19.26 20 LARGE CENTRIFUGAL AIR COMPRESSORS (OVER 200 HP). Complete review and update including section number and title changes. |
| Nov-2025 |
N
|
UFGS 23 03 00 Basic Mechanical Materials and Methods |
Nov-2025 |
N
|
|
New unified section superseding UFGS-23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS |
| Nov-2025 |
N
|
UFGS 23 03 00.00 20 Basic Mechanical Materials and Methods |
Aug-2010 |
D
|
|
Superseded by new unified section UFGS-23 03 00 BASIC MECHANICAL MATERIALS AND METHODSNote: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Nov-2025 |
N
|
UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems |
Nov-2025 |
R
|
|
Revision of August 2009 version. |
| Nov-2025 |
A
|
UFGS 27 05 26 Grounding and Bonding for Communications Systems |
Nov-2025 |
N
|
|
New UFGS section. |
| Nov-2025 |
A
|
UFGS 27 05 29.00 10 Protective Distribution System (PDS) for SIPRNET Communication Systems |
Nov-2025 |
R
|
|
Complete review and update. |
| Nov-2025 |
A
|
UFGS 35 20 16.54 Slide Gates and Actuators |
May-2021 |
C
|
1 |
Incorporated various CCRs. |
| Nov-2025 |
N
|
UFGS 41 22 13.55 Bridge Cranes, Aircraft Maintenance Hangar |
Nov-2025 |
R
|
|
Comprehensive review and significant overhaul of the specification: clarified terminology, revised submittal requirements, updated technical and testing criteria, and alignment with current crane standards. Title changed from BRIDGE CRANES, UNDER RUNNING, AIRCRAFT HANGAR to BRIDGE CRANES, AIRCRAFT MAINTENANCE HANGAR. |
| Nov-2025 |
A
|
UFGS 41 65 10 [Diesel] [Natural Gas] Fueled Engine [Pump] Drives |
Nov-2025 |
N
|
|
Superseding UFGS 41 65 10.00 10 [DIESEL][NATURAL GAS] FUELED ENGINE PUMP DRIVES. Complete review and update including section number change. |
| Nov-2025 |
A
|
UFGS 41 65 10.00 10 [Diesel] [Natural Gas] Fueled Engine Pump Drives |
May-2009 |
D
|
|
Superseded by UFGS 41 65 10 [DIESEL] [NATURAL GAS] FUELED ENGINE [PUMP] DRIVES.Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Nov-2025 |
N
|
UFGS 43 15 00.00 20 Low Pressure Compressed Air Piping (Non-Breathing Air Type) |
Apr-2006 |
D
|
|
Superseded by new unified section UFGS 22 15 26 COMPRESSED AIR PIPING SYSTEMS (UP TO 5000 PSI).Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
| Sep-2025 |
N
|
Standard Template |
Dec-2018 |
C
|
|
In DB RFP Part 4, D40 remove references to UFC 3-600-10N. This has not been an active UFC since app. 2018. The reference occurs in D40, 1.2.1.1; 1.2.2; and 1.3 |
| Aug-2025 |
N
|
UFGS 01 32 16.00 20 Small Project Construction Progress Schedules |
Aug-2018 |
D
|
|
Section archived; Superseded by UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) for NAVFAC Design-Build projects. |
| Aug-2025 |
N
|
UFGS 01 33 29 Sustainability Requirements and Reporting |
Feb-2021 |
C
|
1 |
Section changes to align with UFC 1-200-02 High Performance and Sustainable Building Requirements, Change 3 (July 08, 2025) |
| Aug-2025 |
N
|
UFGS 01 35 13 Special Project Procedures |
Nov-2020 |
C
|
2 |
In response to CCR 16609, Annual Pearl Harbor "Hydrofest" is no longer a standard for NAVFAC HI Projects and has been deleted (3.2.5). |
| Aug-2025 |
N
|
UFGS 01 45 00 Quality Control |
Aug-2023 |
C
|
3 |
In response to CCR 16473, "quality control" has been added to list item d. in paragraph Quality Control (QC) Meetings (1.5.1.3). |
| Aug-2025 |
N
|
UFGS 01 57 19 Temporary Environmental Controls |
Aug-2022 |
C
|
2 |
In response to CCR 16848, updated Recyclables paragraph (1.2.20.6). |
| Aug-2025 |
A
|
UFGS 02 81 00 Transportation and Disposal of Hazardous Materials |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 02 82 00 Asbestos Remediation |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 02 83 00 Lead Remediation |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 02 85 00 Mold Remediation |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 03 30 00 Cast-In-Place Concrete |
Feb-2019 |
C
|
10 |
In response to the following CCRs: 13637 - added ASTM references, updated paragraphs "Admixtures" (2.3.4 e), "Properties and Requirements" (2.5.1 f and g), "Strength ofConcrete Required for Removal of Formwork" (3.3.10), "Mixing" (3.6.2 b), "Concrete Sampling" (3.14.2), "Slump Tests" (3.14.3.1), "Compressive Strength Tests" (3.14.3.4), and "Air Content" (3.14.3.5). Added new paragraph "Slump Flow and Visual Stability Index Tests" (3.14.3.2); CCRs 13637, 15345, and 16154 - updated Submittal Article SD-03 and SD-06; CCR 15427 - replaced reference "ACI 308.1" with “ACI SPEC 308.1"; CCR 15860 - updated paragraph "Normal-Weight Aggregate" (2.3.3.1 a) to include reference to ACI 302.1R, Table 8.5.1; CCR 16032 - added Note and updated "Welding" paragraph (2.6.8 a). |
| Aug-2025 |
N
|
UFGS 03 45 00 Precast Architectural Concrete |
May-2016 |
C
|
3 |
In response to CCR 15942, updated Fabricator Quality Certifications paragraph (1.8.1), with current PCI Certification Types. |
| Aug-2025 |
A
|
UFGS 04 03 00 Conservation Treatment for Period Masonry |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
A
|
UFGS 04 23 00 Glass Unit Masonry |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 05 50 13 Miscellaneous Metal Fabrications |
Aug-2024 |
C
|
1 |
Updated paragraphs CORNER GUARDS (2.4) and MISCELLANEOUS PLATES AND SHAPES (2.9) to require "hot dip galvanized". |
| Aug-2025 |
A
|
UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 07 12 00 Built-Up Bituminous Waterproofing |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 07 13 53 Elastomeric Sheet Waterproofing |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 07 17 00 Bentonite Waterproofing |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 07 18 16 Cold Liquid-Applied Reinforced Polymethyl Methacrylate Roofing |
Aug-2025 |
N
|
|
New UFGS Section to address requirements for PMMA roofing applied over existing or new roofing systems in accordance with UFC 3-110-03 recommendations. |
| Aug-2025 |
N
|
UFGS 07 21 13 Board and Block Insulation |
Aug-2023 |
C
|
1 |
In response to CCR 15491, updated list items in Vapor Retarder under Floor Slab paragraph (2.2.3).. |
| Aug-2025 |
N
|
UFGS 07 21 16 Mineral Fiber Blanket Insulation |
Aug-2023 |
C
|
1 |
In response to CCRs 14183 and 14753 updated requirement for list item b. Mineral Wool in Recycled Materials paragraph (2.1.1). |
| Aug-2025 |
N
|
UFGS 07 31 13 Asphalt Shingles |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
A
|
UFGS 07 31 26 Slate Shingles |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 07 32 13 Concrete Tile Roofing Replacement or Repair |
Aug-2025 |
R
|
|
Complete review and update including title change; from "ROOF TILES" to "CONCRETE TILE ROOFING REPLACEMENT OR REPAIR". |
| Aug-2025 |
N
|
UFGS 07 32 14 Clay Tile Roofing Replacement or Repair |
Aug-2025 |
R
|
|
Complete review and update. |
| Aug-2025 |
N
|
UFGS 07 41 13 Metal Roof Panels |
Aug-2025 |
R
|
|
Complete review and update. |