Release PA UFGS Section Action Change # Nature of Change or Revision
Nov-2015 N UFGS 33 05 23 Trenchless Utility Installation C 1 Removed reference to UFGS Section 33 01 30.16 in subpart 3.5.3, as this section is not yet published
Nov-2015 N UFGS 33 47 13 Pond and Reservoir Liners C 2 Recommended changes from NAVFAC SE regarding revised notes, to use of imperative language and miscellaneous items as submitted via CCR 4563.
Aug-2015 N UFGS 01 11 00 Summary of Work R Revised throughout. Removed Project Environmental Goals covered under UFGS 01 33 29 Sustainability Reporting.
Aug-2015 A UFGS 01 20 01.00 10 Cost and Performance Report D Superseded by UFGS 01 35 13.43 10 Special Project Procedures for Contaminated Sites; Scheduled maintenance update of section.
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 01 22 00.00 10 Price and Payment Procedures R Scheduled maintenance update of section; Superseding UFGS 01 22 00.00 10 Measurement and Payment to comply with CSI MasterFormat.
Aug-2015 N UFGS 01 30 00 Administrative Requirements R Revised throughout.
Aug-2015 A UFGS 01 35 13.43 10 Special Project Procedures for Contaminated Sites N Scheduled maintenance update of section. Superseding UFGS 01 20 01.00 10 COST AND PERFORMANCE REPORT.
Aug-2015 A UFGS 01 78 00 Closeout Submittals C 2 Adjusted Operation and Maintenance Manual requirements. Deleted Preventive Maintenance and list of installed equipment requirements.
Aug-2015 N UFGS 01 78 23 Operation and Maintenance Data R Revised throughout. Coordinated thoroughly with UFGS 01 78 24.00 20 Facility eOMSI and UFGS 01 78 00 Closeout Submittals. Updated training requirements and O&M Manual electronic format.
Aug-2015 N UFGS 01 78 24.00 20 Facility Data Workbook (FDW) C 1 Changes coordinated with section 01 78 23 revision. Moved training and O&M Manual format to 01 78 23. Added resolutions in event of discrepancies in provided FDW, and unsuccessful Field Verification.
Aug-2015 A UFGS 02 42 91 Removal and Salvage of Historic Construction Materials R Nontechnical Title Revision (was Removal and Salvage of Historic Building Materials). Did not change Section date.
Aug-2015 A UFGS 04 21 13.13 Nonbearing Masonry Veneer/Steel Stud Walls D Superseded by UFGS 04 25 13 Metal-Supported Unit Masonry Panels; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 04 23 00 Glass Unit Masonry R Nontechnical Title Revision (was Glass Masonry Units). Did not change Section date.
Aug-2015 A UFGS 04 25 13 Metal-Supported Unit Masonry Panels R Superseding UFGS 04 21 13.13 Nonbearing Masonry Veneer/Steel Stud Walls; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets R Nontechnical Title Revision (was Laminate Clad Architectural Casework). Did not change Section date.
Aug-2015 N UFGS 07 21 16 Mineral Fiber Blanket Insulation C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 07 21 23 Loose Fill Thermal Insulation C 3 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 07 24 00 Exterior Insulation and Finish Systems C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 A UFGS 07 31 26 Slate Shingles R Nontechnical Title Revision (was Slate Roofing). Did not change Section date.
Aug-2015 A UFGS 07 41 13.16 Copper Roof Panels R Superseding UFGS 07 61 01 Copper Roof System; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 07 61 01 Copper Roof System D Superseded by UFGS 07 41 13.16 Copper Roof Panels; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 07 62 10 Copper Sheet Metal Flashing D Superseded by UFGS 07 62 13 Copper Sheet Metal Flashing and Trim; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 07 62 13 Copper Sheet Metal Flashing and Trim R Superseding UFGS 07 62 10 Copper Sheet Metal Flashing; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 07 72 00 Roof Ventilators, Gravity-Type D Superseded by UFGS 07 72 20 Gravity-Type Roof Ventilators; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 07 72 20 Gravity-Type Roof Ventilators R Superseding UFGS 07 72 00 Roof Ventilators, Gravity-Type; Nontechnical number and title revision; Did not change Section date.
Aug-2015 N UFGS 08 01 52 Operation and Maintenance of Wood Windows R Superseding UFGS 08 52 70 Wood Windows - Repair and Rehabilitation; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 08 33 13 Coiling Counter Doors R Nontechnical Title Revision (was Metal Rolling Counter Doors); Did not change Section date.
Aug-2015 S UFGS 08 33 23 Overhead Coiling Doors R Tri-Annual Database Maintenance (TADM) completed
Aug-2015 A UFGS 08 34 53 Security Doors and Frames D Superseded by UFGS 08 34 58 File Room Doors and Frames; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 08 34 58 File Room Doors and Frames R Superseding UFGS 08 34 53 Security Doors and Frames; Nontechnical number and title revision; Did not change Section date.
Aug-2015 S UFGS 08 34 73 Sound Control Door Assemblies C 1 CCR #4297, Subpart 3.3, changed FSTC to ASTC
Aug-2015 N UFGS 08 44 00 Curtain Wall and Glazed Assemblies C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 08 51 13 Aluminum Windows C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 08 51 23 Steel Windows C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 08 52 00 Wood Windows C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 A UFGS 08 52 70 Wood Windows - Repair and Rehabilitation D Superseded by UFGS 08 01 52 Operation and Maintenance of Wood Windows; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 N UFGS 08 53 00 Plastic Windows C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 A UFGS 08 60 45 [Skylights] [ and ] [Translucent Panels] C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 08 81 00 Glazing C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 A UFGS 08 87 16 Fragment Retention Film for Glass D Superseded by UFGS 08 87 23.13 Safety Films; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 08 87 23.13 Safety Films R Superseding UFGS 08 87 16 Fragment Retention Film for Glass; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 09 01 90.50 Preparation of Historic Wood and Metal Surfaces for Painting R Superseding UFGS 09 97 30 Preparation of Historic Wood and Metal Surfaces for Painting; Nontechnical Section number revision; Did not change Section date.
Aug-2015 A UFGS 09 24 23 Cement Stucco R Nontechnical Title Revision (was Stucco). Did not change Section date.
Aug-2015 A UFGS 09 35 16 Chemical-Resistant Quarry Tiling R Nontechnical Title Revision (was Chemical-Reistant Quarry Tile). Did not change Section date.
Aug-2015 A UFGS 09 66 13 Portland Cement Terrazzo Flooring R Nontechnical Title Revision (was Portland Cement Terrazzo). Did not change Section date
Aug-2015 A UFGS 09 66 16 Terrazzo Floor Tile R Nontechnical Title Revision (was Terrazzo Tile). Did not change Section date.
Aug-2015 A UFGS 09 66 23 Resinous Matrix Terrazzo Flooring R Nontechnical Title Revision (was Resinous Terrazzo Flooring). Did not change Section date.
Aug-2015 A UFGS 09 83 13 Acoustical Wall Coating R Nontechnical Title Revision (was Acoustical Wall Treatment). Did not change Section date
Aug-2015 A UFGS 09 97 01.00 10 Metallizing Hydraulic Structures D Superseded by UFGS 09 97 10.00 10 Metallic Coatings for Hydraulic Structures; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 09 97 10.00 10 Metallic Coatings for Hydraulic Structures R Superseding UFGS 09 97 01.00 10 Metallizing Hydraulic Structures; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 09 97 30 Preparation of Historic Wood and Metal Surfaces for Painting D Superseded by UFGS 09 01 90.50 Preparation of Historic Wood and Metal Surfaces for Painting; Nontechnical Section number change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 10 10 00 Visual Communications Specialties D Superseded by UFGS 10 11 00 Visual Display Units; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 10 11 00 Visual Display Units R Superseding UFGS 10 10 00 Visual Communications Specialties; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 10 14 00.10 Exterior Signage R Superseding UFGS 10 14 01 Exterior Signage; Nontechnical Section number revision; Did not change Section date.
Aug-2015 A UFGS 10 14 01 Exterior Signage D Superseded by UFGS 10 14 00.10 Exterior Signage; Nontechnical Section number change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 10 26 00 Wall and Door Protection R Superseding UFGS 10 26 13 Wall and Corner Guards ; Nontechnical number and title revision; Did not change Section date
Aug-2015 A UFGS 10 26 13 Wall and Corner Guards D Superseded by UFGS 10 26 00 Wall and Door Protection; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 11 13 10 Dock Levelers D Superseded by UFGS 11 13 19.13 Loading Dock Levelers; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 11 13 19.13 Loading Dock Levelers R Superseding UFGS 11 13 10 Dock Levelers; Nontechnical number and title revision; Did not change Section date.
Aug-2015 N UFGS 11 72 13 Medical Equipment, Miscellaneous C 1 CCR 4172: removed reference ASTM A167, withdrawn with no replacement
Aug-2015 N UFGS 11 74 00 Dental Equipment C 1 CCR 4173: removed reference ASTM A167, withdrawn with no replacement
Aug-2015 A UFGS 12 50 00 Furniture Systems D Superseded by UFGS 12 59 00 Systems Furniture; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 12 59 00 Systems Furniture R Superseding UFGS 12 50 00 Furniture Systems; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 12 61 13 Upholstered Audience Seating R Superseding UFGS 12 65 00 Fixed Seating; Nontechnical number and title revision; Did not change Section date.
Aug-2015 A UFGS 12 65 00 Fixed Seating D Superseded by UFGS 12 61 13 Upholstered Audience Seating;Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 N UFGS 13 17 43 Hydrotherapy Equipment C 1 CCR 4174: removed reference ASTM A167, withdrawn with no replacement
Aug-2015 A UFGS 13 27 54.00 10 Electromagnetic (EM) Shielding D Superseded by UFGS 13 49 20.00 10 RFI/EMI Shielding; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 A UFGS 13 49 20.00 10 RFI/EMI Shielding R Superseding UFGS 13 27 54.00 10 Electromagnetic (EMI) Shielding; Nontechnical number and title revision; Did not change Section date.
Aug-2015 N UFGS 22 00 00 Plumbing, General Purpose C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 S UFGS 22 66 53.00 40 Laboratory Chemical-Waste and Vent Piping R Tri-Annual Database Maintenance (TADM) completed
Aug-2015 A UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems C 4 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 03 00.00 20 Basic Mechanical Materials and Methods C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 S UFGS 23 05 48.00 40 Vibration and Seismic Controls for HVAC Piping and Equipment R Tri-Annual Database Maintenance (TADM) completed
Aug-2015 A UFGS 23 07 00 Thermal Insulation for Mechanical Systems C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 09 53.00 20 Space Temperature Control Systems C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 S UFGS 23 22 23.00 40 Steam Condensate Pumps R Tri-Annual Database Maintenance (TADM) completed
Aug-2015 A UFGS 23 52 00 Heating Boilers C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 33.01 20 Steam Heating Plant Watertube (Shop Assembled) Coal/Oil or Coal C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 33.02 20 Steam Heating Plant Watertube (Field Erected) Coal/Oil or Coal C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 33.03 20 Water-Tube Boilers, Oil/Gas or Oil C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 43.00 20 Low Pressure Water Heating Boilers (Under 800,000 Btu/hr Output) C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 46.00 20 Low Pressure Water Heating Boilers (Over 800,000 Btu/hr Output) C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 49.00 20 Steam Boilers and Equipment (500,000 - 18,000,000 Btu/hr) C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 52 53.00 20 Steam Boilers and Equipment (18,000,000 - 60,000,000 Btu/hr) C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 54 19 Building Heating Systems, Warm Air C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 64 00 Packaged Water Chillers, Absorption Type C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 64 10 Water Chillers, Vapor Compression Type C 3 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems C 3 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 65 00 Cooling Towers and Remote Evaporatively-Cooled Condensers C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 69 00.00 20 Refrigeration Equipment for Cold Storage C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 A UFGS 23 71 19 Thermal Energy Storage System: Ice-On-Coil C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 76 00.00 20 Evaporative Cooling System C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 81 00.00 20 Unitary Air Conditioning Equipment C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 81 23.00 20 Computer Room Air Conditioning Units C 1 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 81 47 Water-Loop and Ground-Loop Heat Pump Systems C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 23 82 00.00 20 Terminal Heating Units C 2 UFGS sustainability/energy updates to comply with Navy and DoD policies to enforce requirements of UFC 1-200-02 "High Performance and Sustainable Building Requirements".
Aug-2015 N UFGS 31 23 00.00 20 Excavation and Fill C 2 In response to CCR 4371: reference update
Aug-2015 N UFGS 33 05 23 Trenchless Utility Installation N New UFGS Section; Superseding UFGS 33 05 23.19 Trenchless Excavating using Microtunneling
Aug-2015 A UFGS 33 05 23.19 Trenchless Excavation Using Microtunneling D Superseded by UFGS 33 05 23 Trenchless Utility Installation; Nontechnical number and title change
Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives.
Aug-2015 N UFGS 33 56 13.13 Steel Tanks With Fixed Roofs R UFGS has been revised throughout. Modifications included references, submittals, new jet fuels and requirements for the following in accordance with the update of DoD Aboveground Storage Tank Standard AW 78-24-27: columns, pressure/vacuum vents, antirotation cables, center roof vents, roof manholes, roof circulation vent/inspection hatches, water draw-off systems, sidestream filtration systems, weld inspections and stilling wells.