Below is a listing of the Revisions and Changes made to UFGS Sections for each release. You can narrow the list by selecting a UFGS Release date from the drop-down and clicking 'Apply'.
| KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA [ARCHIVED] |
|---|---|---|---|---|---|
| ACTION | N New | R Revision | C Change | D Deletion |
| Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
|---|---|---|---|---|---|---|
| Feb-2016 | S | UFGS 01 33 00 Submittal Procedures | May-2011 | C | 7 | Incorporated outstanding CCR's. |
| Feb-2016 | A | UFGS 01 50 00 Temporary Construction Facilities and Controls | Aug-2009 | C | 3 | Added provision for dumpsters tailored to NAVFAC SE |
| Feb-2016 | A | UFGS 04 21 26 Glazed Structural Clay Tile and Prefaced Concrete Masonry | Nov-2009 | D | Requirements transferred to UFGS 04 20 00 UNIT MASONRY (11/15 Release) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 04 25 13 Metal-Supported Unit Masonry Panels | Oct-2007 | D | Requirements transferred to UFGS 04 20 00 UNIT MASONRY (11/15 Release) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | N | UFGS 05 51 33 Metal Ladders | Feb-2016 | R | Revised to incorporate the addition of ladder safety device requirement and editorial changes. | |
| Feb-2016 | N | UFGS 06 20 00 Finish Carpentry | Feb-2016 | R | Complete revision; revised throughout to incorporate ccrs 2803, 1484,and 2424; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 12 00 Built-Up Bituminous Waterproofing | Feb-2016 | R | Complete revision; revised throughout to incorporate CCR 3686 ; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 13 53 Elastomeric Sheet Waterproofing | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 3687, 3463; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 17 00 Bentonite Waterproofing | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 2803, 1484,and 2424; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 21 13 Board and Block Insulation | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 2820, 3234; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 22 00 Roof and Deck Insulation | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 4254, 2807; update format and editorial changes. | |
| Feb-2016 | N | UFGS 07 92 00 Joint Sealants | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 2376 and 3692 update format and editorial changes | |
| Feb-2016 | N | UFGS 08 71 00 Door Hardware | Feb-2016 | R | Complete revision; revised throughout to incorporate CCRs 4818, 1613, 3999, 2450, 2451, 2762, 1612, 3384, and 3386; update format and editorial changes | |
| Feb-2016 | A | UFGS 09 30 10 Ceramic, Quarry, and Glass Tiling | Nov-2013 | C | 1 | Corrected Section title, was CEMENT TILING, QUARRY TILING, AND PAVER TILING; corrected tailoring |
| Feb-2016 | N | UFGS 09 67 23.16 Fuel Resistive Resinous Flooring, 5-Coat System | Aug-2010 | C | 1 | Change to clarify that vendor products named are pretested for specification compliance. These and additional vendors and products may be submitted for review of compliance with test results in accordance with this specification; editorial updates. |
| Feb-2016 | N | UFGS 09 97 13.26 Coating of Steel Waterfront Structures, Zero VOC, (SZC) Splash Zone Coating | Feb-2016 | R | Revision of 2006 version; Title changed from COATING OF STEEL WATERFRONT STRUCTURES; This spec is a complete revision to reflect a new and different product. The spec was modified to move from Coal Tar Epoxy and Epoxy products to low VOC polysulfide modified novolac epoxy. Updates to QA/QC procedures and reporting requirements were also added. | |
| Feb-2016 | N | UFGS 09 97 13.27 High Performance Coating for Steel Structures | Feb-2016 | R | This spec is a complete revision to reflect a new and different product. The spec was modified to move from Epoxy/ Polyurethane MIL Spec products to low VOC polysulfide modified novolac epoxy. Updates to QA/QC procedures and reporting requirements were also added. | |
| Feb-2016 | N | UFGS 11 41 11 Refrigerated and Frozen Food Storage Equipment | Feb-2016 | R | Complete revision; updated format and editorial changes. | |
| Feb-2016 | N | UFGS 11 42 00 Food Preparation Equipment | Feb-2016 | R | Complete revision; updated format and editorial changes. | |
| Feb-2016 | N | UFGS 13 21 26 Cold-Storage Rooms (Prefabricated Panel Type) | Feb-2016 | R | Complete revision; updated format and editorial changes | |
| Feb-2016 | A | UFGS 22 10 00.00 10 Vertical Pumps, Axial-Flow and Mixed-Flow Impeller-Type | Jul-2007 | D | Superseded by UFGS 35 45 01 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 22 11 23.00 10 Submersible Pump, Axial-Flow and Mixed-Flow Type | Jul-2007 | D | Superseded by UFGS 35 45 02.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 23 40 00.00 10 Chemical, Biological, and Radiological (CBR) Air Filtration System | Oct-2007 | D | Superseded by UFGS 23 44 00.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | S | UFGS 23 41 13.00 40 Panel Filters | Feb-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2016 | A | UFGS 23 44 00.00 10 Chemical, Biological, and Radiological (CBR) Air Filtration System | Feb-2016 | N | Superseding UFGS 23 40 00.00 10 of the same title. Complete review and update to include renaming for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 23 50 52.00 10 Central High Temperature Water (HTW) Generating Plant and Auxiliaries | Feb-2016 | N | Superseding UFGS 33 60 00.00 10 of the same title. Complete review and update to include renaming for compliance with current MasterFormat. | |
| Feb-2016 | N | UFGS 23 82 00.00 20 Terminal Heating Units | Feb-2016 | R | Revised throughout to incorporate CCRs 1734, 4179, 4406 and 4716. Title changed from TERMINAL HEATING AND COOLING UNITS. Modifications included, references, infrared heaters and electrical work. | |
| Feb-2016 | S | UFGS 27 21 00.00 40 Intercommunication System | Feb-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Feb-2016 | S | UFGS 27 21 00.00 40 Intercommunication System | Feb-2016 | R | Tri-Annual Database Maintenance which includes, updating CSI Section Format per latest UFC 1-300-02; modified text in General Not and Part 1, deleted Subpart 1.2, 1.3, 1.3.1, 1.3.2, 1.3.3,added Subpart 2.1 - 2.1.1.3, modified 2.2.4 - 2.2.4.2; Submittal Article compliance, Imperative language | |
| Feb-2016 | N | UFGS 31 31 16.19 Termite Control Barriers | Feb-2016 | R | Section and title revised to combine UFGS 31 31 16.19 (was) MESH TERMITE CONTROL BARRIER SYSTEM and UFGS 31 31 16.20 BASALTIC TERMITE BARRIER and UFGS 31 31 16.21 MESH TERMITE BARRIER (deleted February 2015) to reduce specifications containing similar content and updated to reflect current criteria format. | |
| Feb-2016 | N | UFGS 31 31 16.20 Basaltic Termite Barrier | Apr-2006 | D | Superseded by UFGS 31 31 16.19 Termite Control Barriers Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | N | UFGS 32 01 13.63 Gilsonite Modified Asphalt Emulsion Seal Coats | Feb-2016 | N | New UFGS Section | |
| Feb-2016 | S | UFGS 33 05 23.13 Utility Horizontal Directional Drilling | Nov-2013 | C | 1 | Performed updating of Section Format, imperative language, formatting review, and Submittal Article clean up |
| Feb-2016 | A | UFGS 33 30 00 Sanitary Sewerage | Apr-2008 | C | 4 | Additional requirements to prevent cross connection of sanitary with storm sewer |
| Feb-2016 | A | UFGS 33 45 00.00 10 Speed Reducers for Storm Water Pumps | Apr-2008 | D | Superseded by UFGS 35 45 03.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 51 15 Natural-Gas / Liquid Petroleum Gas Distribution Pipelines | Feb-2016 | R | Complete review and update. | |
| Feb-2016 | A | UFGS 33 60 00.00 10 Central High Temperature Water (HTW) Generating Plant and Auxiliaries | Apr-2008 | D | Superseded by UFGS 23 50 52.00 10 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 60 01 Valves, Piping, and Equipment in Valve Manholes | Apr-2008 | D | Superseded by UFGS 33 61 13.19 with the same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 61 00 Prefabricated Underground Heating / Cooling Distribution System | Apr-2008 | D | Superseded by UFGS 33 61 13.13 PREFABRICATED UNDERGROUND HYDRONIC ENERGY DISTRIBUTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 61 13.13 Prefabricated Underground Hydronic Energy Distribution | Feb-2016 | N | Superseding UFGS 33 61 00 PREFABRICATED UNDERGROUND HEATING/COOLING DISTRIBUTION SYSTEM. Complete review and update to include renaming and re-titling for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 33 61 13.19 Valves, Piping, and Equipment in Valve Manholes | Feb-2016 | N | Superseding UFGS 33 60 01 of the same title. Complete review and update to include renaming for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 33 61 15 Heat Distribution Systems in Concrete Trenches | Jul-2006 | D | Superseded by UFGS 33 63 13.19 CONCRETE TRENCH HYDRONIC AND STEAM ENERGY DISTRIBUTION Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Feb-2016 | A | UFGS 33 63 13.19 Concrete Trench Hydronic and Steam Energy Distribution | Feb-2016 | N | Superseding UFGS 33 61 15 HEAT DISTRIBUTION SYSTEMS IN CONCRETE TRENCHES. Complete review and update to include renaming and re-titling for compliance with current MasterFormat. | |
| Feb-2016 | A | UFGS 35 45 01 Vertical Pumps, Axial-Flow and Mixed-Flow Impeller-Type | Feb-2016 | N | Superseding UFGS 22 10 00.00 10 VERTICAL PUMPS, AXIAL-FLOW AND MIXED-FLOW IMPELLER TYPE. Complete review and update. | |
| Feb-2016 | A | UFGS 35 45 02.00 10 Submersible Pump, Axial-Flow and Mixed-Flow Type | Feb-2016 | N | Superseding UFGS 22 11 23.00 10 SUBMERSIBLE PUMP, AXIAL-FLOW AND MIXED-FLOW TYPE. Complete review and update. | |
| Feb-2016 | A | UFGS 35 45 03.00 10 Speed Reducers for Storm Water Pumps | Feb-2016 | N | Superseding UFGS 33 45 00.00 10 SPEED REDUCERS FOR STORM WATER PUMPS. | |
| Nov-2015 | N | UFGS 01 32 16.00 20 Small Project Construction Progress Schedules | Feb-2015 | C | 2 | Revised the Time Impact Analysis (TIA) action for Concurrent Delays. |
| Nov-2015 | N | UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) | Feb-2015 | C | 2 | Revised the Time Impact Analysis (TIA) action for Concurrent Delays |
| Nov-2015 | N | UFGS 01 33 29 Sustainability Requirements and Reporting | Feb-2015 | C | 1 | Alignment with sustainable policies. |
| Nov-2015 | N | UFGS 01 35 26 Governmental Safety Requirements | Nov-2015 | R | Updated to EM 385-1-1 (NOV 2014) requirements and terms including clarifying requirements for Dive Protection, Fall Protection, Load Handling Equipment, and Electrical. Added Subcontractor Safety requirements for Navy only. | |
| Nov-2015 | A | UFGS 01 35 29.13 Health, Safety, and Emergency Response Procedures for Contaminated Sites | Nov-2015 | R | UFGS refresh review and update in conjunction with review and update of UFGS 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS | |
| Nov-2015 | A | UFGS 01 57 16 Temporary Pest Control | Apr-2008 | D | Superseded by UFGS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | N | UFGS 01 57 19 Temporary Environmental Controls | Nov-2015 | N | Unification of the following sections and update to current requirements: 01 57 19.00 20 TEMPORARY ENVIRONMENTAL CONTROLS, 01 57 20.00 10 ENVIRONMENTAL PROTECTION, 01 57 23 TEMPORARY STORMWATER POLLUTION CONTROL, and 01 57 16 TEMPORARY PEST CONTROL | |
| Nov-2015 | N | UFGS 01 57 19.00 20 Temporary Environmental Controls | Nov-2011 | D | Superseded by UFGS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | N | UFGS 01 57 19.01 20 Supplemental Temporary Environmental Controls | Nov-2015 | R | Unification with UFGS 01 57 19.02 TEMPORARY ENVIRONMENTAL CONTROLS (GTMO), coordination with UFGS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS, and update of regional requirements. | |
| Nov-2015 | N | UFGS 01 57 19.02 Temporary Environmental Controls (GTMO) | Jan-2008 | D | Superseded by UFGS 01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 01 57 20.00 10 Environmental Protection | Apr-2006 | D | Superseded by UFGS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 01 57 23 Temporary Storm Water Pollution Control | Apr-2008 | D | Superseded by UFGS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 02 82 13.00 10 Asbestos Abatement | Feb-2010 | R | Superseding UFGS 02 82 14.00 10 Asbestos Hazard Control Activities; Nontechnical number and title revision; Did not change Section date. | |
| Nov-2015 | A | UFGS 02 82 14.00 10 Asbestos Hazard Control Activities | Feb-2010 | D | Superseded by UFGS 02 82 13.00 10 Asbestos Abatement; Nontechnical number and title change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 04 01 00.91 Restoration and Cleaning of Masonry in Historic Structures | May-2012 | D | Superseded by UFGS 04 01 20.70 UNIT MASONRY CLEANING AND RESTORATION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 04 01 20 Rehabilitation of Reinforced and Unreinforced Masonry Walls Using FRP Composite Structural Repointing | Oct-2007 | D | Superseded by UFGS 04 01 20.73 MASONRY STRENGTHENING USING FRP BARS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 04 01 20.70 Unit Masonry Cleaning and Restoration | Nov-2015 | N | Superseding UFGS 04 01 00.91 RESTORATION AND CLEANING OF MASONRY IN HISTORIC STRUCTURES | |
| Nov-2015 | A | UFGS 04 01 20.73 Masonry Strengthening Using FRP Bars | Nov-2015 | N | Superseding UFGS 04 01 20 REHABILITATION OF REINFORCED AND UNREINFORCED MASONRY WALLS USING FRP COMPOSITE STRUCTURAL REPOINTING | |
| Nov-2015 | A | UFGS 04 01 20.75 Masonry Strengthening Using Surface Applied FRP Composites | Nov-2015 | N | Superseding UFGS 04 01 21 REHABILITATION OF REINFORCED AND UNREINFORCED MASONRY WALLS USING SURFACE APPLIED FRP COMPOSITES | |
| Nov-2015 | A | UFGS 04 01 21 Rehabilitation of Reinforced and Unreinforced Masonry Walls Using Surface Applied FRP Composites | Oct-2007 | D | Superseded by UFGS 04 01 20.75 Masonry Strengthening Using Surface Applied FRP Composites. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 04 20 00 Unit Masonry | Nov-2015 | R | Title changed from Masonry. UFGS refresh review and update | |
| Nov-2015 | A | UFGS 04 23 00 Glass Unit Masonry | Nov-2015 | R | UFGS refresh review and update. | |
| Nov-2015 | A | UFGS 06 61 16 Solid Surfacing Fabrications | Aug-2010 | R | Nontechnical Title Revision (was Solid Polymer (Solid Surfacing) Fabrications). Did not change Section date. | |
| Nov-2015 | A | UFGS 09 06 90 Schedules for Painting and Coating | May-2009 | R | Nontechnical Title Revision (was Color Schedule). Did not change Section date. | |
| Nov-2015 | A | UFGS 09 30 10 Ceramic, Quarry, and Glass Tiling | Nov-2013 | R | Superseding UFGS 09 30 13 Ceramic Tiling; Nontechnical number and title revision; Did not change Section date. | |
| Nov-2015 | A | UFGS 09 30 13 Ceramic Tiling | Nov-2013 | D | Superseded by UFGS 09 30 10 Cement Tiling, Quarry Tiling, and Paver Tiling; Nontechnical number and title change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 09 64 29 Wood Strip and Plank Flooring | Aug-2010 | R | Nontechnical Title Revision (was Wood Strip Flooring). Did not change Section date | |
| Nov-2015 | A | UFGS 09 69 13 Rigid Grid Access Flooring | Nov-2015 | R | UFGS refresh review and update. | |
| Nov-2015 | A | UFGS 09 69 19 Stringerless Access Flooring | Nov-2015 | R | UFGS refresh review and update. | |
| Nov-2015 | S | UFGS 12 31 00 Manufactured Metal Casework | Nov-2014 | C | 1 | Subpart 2.8, SRF 09 06 90 changed title from Color Schedule to Schedules for Painting and Coating |
| Nov-2015 | S | UFGS 12 32 00 Manufactured Wood Casework | Nov-2013 | C | 1 | Subpart 2.3.3, SRF 09 06 90 changed title from Color Schedule to Schedules for Painting and Coating |
| Nov-2015 | S | UFGS 12 34 00 Manufactured Plastic Casework | Nov-2014 | C | 1 | Subpart 2.3.2, SRF 09 06 90 changed title from Color Schedule to Schedules for Painting and Coating |
| Nov-2015 | A | UFGS 12 35 20 Foodservice Casework, Countertops, and Accessories | Aug-2010 | D | Superseded by UFGS 12 35 39 Commercial Kitchen Casework; UFGS Nontechnical number and title revision. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 12 35 39 Commercial Kitchen Casework | Aug-2010 | R | Superseding UFGS 12 35 20 Foodservice Casework, Countertops, and Accessories; Nontechnical number and title revision; Did not change Section date. | |
| Nov-2015 | A | UFGS 12 35 70 Healthcare Casework | Aug-2010 | R | Nontechnical Title Revision (was Medical and Dental Casework). Did not change Section date. | |
| Nov-2015 | S | UFGS 12 36 00 Countertops | Aug-2015 | C | 1 | Subpart 2.2.2, Section Reference (SRF) 09 06 90 changed title from "Color Schedule" to "Schedules for Painting and Coating" |
| Nov-2015 | S | UFGS 12 48 13 Entrance Floor Mats and Frames | Feb-2014 | C | 2 | Subpart 2.4, SRF 09 06 90 changed title from COLOR SCHEDULE to Schedules FOR PAINTING AND COATING |
| Nov-2015 | A | UFGS 13 49 10 X-Ray Shielding | Feb-2009 | R | Superseding UFGS 13 49 19 with no title change; Nontechnical number revision; Did not change Section date. | |
| Nov-2015 | A | UFGS 13 49 19 X-Ray Shielding | Feb-2009 | D | Superseded by UFGS 13 49 10 X-Ray Shielding; Nontechnical section number change. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | N | UFGS 22 00 00 Plumbing, General Purpose | Nov-2015 | R | Revised throughout to incorporate CCRs 1605, 2764, 2765, 2832, 3301, 3391, 3891, 4118, 4159, 4209, 4411, and 4437. Modifications included references, plumbing system testing, performance of gas storage-type water heaters and requirements for the following products: drinking-water coolers and floor sinks. | |
| Nov-2015 | N | UFGS 23 05 93 Testing, Adjusting, and Balancing for HVAC | Nov-2015 | R | Revised throughout to incorporate CCRs 290, 840, 1224, 2713, 3697, 4315, 4416, 4426, 4430, 4433 and 4480. Modifications included administrative changes to correct tailoring option and submittal register, submittals, quality assurance, instrument calibration certificates, DALT procedures, TAB procedures, work descriptions of participants, and DALT and TAB reports. | |
| Nov-2015 | A | UFGS 23 09 00 Instrumentation and Control for HVAC | Nov-2015 | N | Superseding UFGS 23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS and UFGS 23 09 23.13 20 BACnet DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC | |
| Nov-2015 | A | UFGS 23 09 13 Instrumentation and Control Devices for HVAC | Nov-2015 | N | Superseding UFGS 23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS and UFGS 23 09 23.13 20 BACnet DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC | |
| Nov-2015 | A | UFGS 23 09 23 LonWorks Direct Digital Control for HVAC and Other Building Control Systems | May-2011 | D | Superseded by UFGS 23 09 00 Instrumentation and Control for HVAC, UFGS 23 09 23.01 LONWORKS Direct Digital Control for HVAC and Other Building Control Systems, UFGS 23 09 23.02 BACNET Direct Digital Control for HVAC and Other Building Control Systems, UFGS 23 09 13 Instrumentation and Control Devices for HVAC, and UFGS 23 09 93 Sequences or Operation for HVAC Control. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |
|
| Nov-2015 | A | UFGS 23 09 23.01 Lonworks Direct Digital Control for HVAC and Other Building Control Systems | Nov-2015 | N | Superseding UFGS 23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS and UFGS 23 09 23.13 20 BACnet DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC | |
| Nov-2015 | A | UFGS 23 09 23.02 BACnet Direct Digital Control for HVAC and Other Building Control Systems | Nov-2015 | N | Superseding UFGS 23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS and UFGS 23 09 23.13 20 BACnet DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC | |
| Nov-2015 | N | UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC | Nov-2015 | R | Revised throughout to incorporate numerous modifications. Modifications included references, definitions, control system components list, BACnet communication architecture schematic, submittals, DDC system, BACnet building controller, stand-alone controllers, internal clock, communications ports, digital controller cabinet, programming, trending, device management, BACnet operator workstation, notebook computer, software, BACnet discovery tool, energy metering, actuators, power line surge protection, variable frequency (motor) drives, BACnet naming and addressing, BACnet routers and protocol gateways, and performance verification testing plan. | |
| Nov-2015 | A | UFGS 23 09 93 Sequences of Operation for HVAC Control | Nov-2015 | N | Superseding UFGS 23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING CONTROL SYSTEMS | |
| Nov-2015 | N | UFGS 23 21 13.00 20 Low Temperature Water (LTW) Heating System | Apr-2006 | C | 1 | Deleted paragraph 2.1.3 MECHANICAL PIPE COUPLING SYSTEM and subparagraphs 2.1.3.1, 2.1.3.2, 2.1.3.3 |
| Nov-2015 | A | UFGS 25 10 10 Utility Monitoring and Control System (UMCS) Front End and Integration | Nov-2015 | R | Update technical requirements to be in agreement with UFGS 23 09 00 Instrumentation and Control for HVAC, UFGS 23 09 23.01 LonWorks Direct Digital Control for HVAC and Other Building Control Systems, and UFGS 23 09 23.02 BACNet Direct Digital Control for HVAC and Other Building Control Systems and to update cybersecurity requirements. | |
| Nov-2015 | S | UFGS 26 53 00.00 40 Exit Signs | Nov-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
| Nov-2015 | A | UFGS 31 00 00 Earthwork | Aug-2008 | C | 1 | Added fill lift height and moisture requirements as recommended in approved CCR 4098 |
| Nov-2015 | A | UFGS 32 12 15.13 Asphalt Paving for Airfields | Nov-2015 | R | UFGS refresh review and update. | |
| Nov-2015 | A | UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements | Nov-2015 | R | UFGS refresh review and update. |