Transmittal Report:

Created by AutoCAD eTransmit Wednesday, December 09, 2015, 3:45 PM.



Drawing:

This is a transmittal based on multiple drawings.



Files:





Root Drawings:	1401800M-001.dwg

	MechIndexDoNotPrint.dwg

	1401800M-002A.dwg

	1401800M-002B.dwg

	1401800M-003.dwg

	1401800M-101A.dwg

	1401800M-101B.dwg

	1401800M-102A.dwg

	1401800M-103.dwg

	1401800M-301A.dwg

	1401800M-301B.dwg

	1401800M-501.dwg

	1401800M-502.dwg

	1401800M-503.dwg

	1401800M-504A.dwg

	1401800M-504B.dwg

	1401800M-505A.dwg

	1401800M-601.dwg

	1401820MHP-101.dwg

	1401820MHP-501.dwg

	1401820MHP-502.dwg



AutoCAD Drawing (External) References:

	xref\1401800BS-FULL.dwg

	xref\1401800M-PPagtanks.dwg

	xref\1401800S-NP10.1_Horz_Tanks_COL_PLAN.dwg

	xref\1401800C-SP00A.dwg

	xref\1401800M-PPloadingpad.dwg

	xref\1401800M-PPoffloadpad.dwg

	xref\1401800S-NP07_canopy.dwg

	xref\1401800M-PPugtanks.dwg

	xref\1401800C-SP00U.dwg

	xref\1401800C-SP00.dwg

	xref\1201132M-PPhorztanks.dwg

	xref\1201132M-PPoffloadpad.dwg

	xref\1201132S-NP07_canopy.dwg

	xref\1401800M-PPloadingpadelev.dwg

	xref\1401800M-PPagtankelev.dwg

	xref\1401800M-PPoffloadelev.dwg

	xref\1401800M-PPugtankelev.dwg

	xref\1401800A-FPfscb.dwg

	xref\1401800M-MHFSCB.dwg

	xref\1201132M-MHFSCB.dwg

	xref\1401800P-PPFSCB.dwg

	xref\1201132A-FPfscb.dwg



AutoCAD Color-dependent Plot Style Table File References:

	PlotCfgs\aecstdbandw.ctb



JPEG image References:

	Textures\Concrete.Cast-In-Place.Exposed Aggregate.Coarse.jpg

	Textures\Concrete.Cast-In-Place.Flat.Grey.1.jpg

	Textures\Doors - Windows.Metal Doors - Frames.Aluminum Frame.Anodized.Dark Bronze.Satin.jpg

	Textures\Doors - Windows.Metal Doors - Frames.Steel.Galvanized.jpg

	Textures\Doors - Windows.Wood Doors.Ash.jpg

	Textures\Finishes.Gypsum Board.Painted.White.bump.jpg

	Textures\Finishes.Gypsum Board.Painted.White.jpg

	Textures\Finishes.Metal Framing Systems.Furring.jpg

	Textures\Finishes.Metal Framing Systems.Stud.jpg

	Textures\Masonry.Unit Masonry.CMU.Stretcher.Running.jpg

	Textures\Sitework.Planting.Grass.Short.jpg

	Textures\Sitework.Planting.Grass.Thick.jpg

	Textures\Sitework.Planting.Gravel.Crushed.jpg

	Textures\Sitework.Planting.Gravel.Mixed.jpg

	Textures\Sitework.Planting.Sand.jpg

	Textures\Sitework.Planting.Soil.jpg



AutoCAD Plotter Configuration File References:

	PlotCfgs\DWG To PDF.pc3



The following files were excluded from the transmittal:

	acad.fmp

	Fonts\simplex.shx

	Fonts\arial.ttf

	Fonts\romans.shx

	Fonts\txt.shx

	Fonts\arialbd.ttf

	Fonts\romantic.ttf

	archstyl.(shx,ttf)

	Textures\Sitework.Paving & Surfacing.Asphalt.1.jpg

	Textures\Sitework.Paving - Surfacing.Asphalt.jpg

	Fonts\calibri.ttf

	Fonts\ltypeshp.shx

	ENGINEERING.(shx,ttf)

	LOW_RES_FILLED.(shx,ttf)

	CHAR_FAST_FONT.(shx,ttf)

	Catalogs\USS16-3100.pdf

	PlotCfgs\CutePDF Writeraaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa.pc3

	xref\1401800E-LP02FSCB.dwg

	Fonts\bold.shx

	Fonts\swiss.ttf

	Fonts\romanD.shx



The following files could not be located:

	archstyl.(shx,ttf)

	Textures\Sitework.Paving & Surfacing.Asphalt.1.jpg

	Textures\Sitework.Paving - Surfacing.Asphalt.jpg

	ENGINEERING.(shx,ttf)

	LOW_RES_FILLED.(shx,ttf)

	CHAR_FAST_FONT.(shx,ttf)

	Catalogs\USS16-3100.pdf

	PlotCfgs\CutePDF Writeraaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa.pc3





Notes for distribution:



.DWG external reference files:

External reference (xref) paths may be present.  Make sure these paths work or that the root drawing is using the correct references.

eTransmit does not include files required by xrefs unless they are also required by the root drawing.  In particular, plot style tables and overlay xrefs that are not used by the root drawing are omitted



.PC3 printer configuration files:

Please copy these files to the AutoCAD Printer Configuration Search Path directory.



.CTB/.STB plot style tables:

Please copy these files to the AutoCAD Plot Style Table Search Path directory.



Material texture files:

Please copy these files to the AutoCAD Texture Maps Search Path directory.



The AutoCAD variable FONTALT was set to:

C:\Users\ahughes\appdata\roaming\autodesk\mep 2013\enu\support\simplex.shx

Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings.  All text styles with missing fonts are automatically set to this font.